The building codes and building science for.
Roof venting formula.
Up to 6 12 roof pitch use the standard formula as explained in this article.
7 12 to 10 12 roof pitches increase the amount of ventilation by 20 percent.
And this guideline you ll need a minimum of.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
What is the proper ratio of soffit intake to ridge outlet.
Building codes typically echo the administration s guidelines.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
One of the easiest and most effective ways of ventilation on a roof is to use a ridge vent.
Here s a rule of thumb to follow.
Next divide that number by 2.
Generally as the roof pitch increases the volume inside the attic also increases along with the amount of needed attic ventilation.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Our roof is 50 feet long so using a standard product we will get 900 square inches of ventilating space.
A ridge vent is installed at the peak of the roof where the hot air rises to.
Vent roofs with steeples towers or cupolas can be found in different buildings from barns to cathedrals.
Now you know how many square inches of attic roof venting you need for the roof and soffit.
How to specify the proper roof intake and outlet vent area ratios to stop building heat loss and provide proper attic venting to avoid condensation ice dam leaks mold roof structure damage table of types of ridge vents and net free venting area per linear foot list of roof outlet ventilation products comparing equivalent ventilation area provided by each questions answers about attic moisture condensation ventilation.
Vents are rated by their net free area or the amount of space for air to flow in or out.
The idea of roof vents existed for hundreds of years with natural vents employed in chinese buildings during the tang dynasty natural ventilation ducts in the buddhist monks caves and wind catchers incorporated in arabian architecture.
You can calculate attic ventilation requirements by determining the square footage of your attic floor its width times its length and compare that to the total required net free area nfa.
So the ridge ventilation has exceeded the minimum requirement.
Standard ridge vent produces 18 square inches of ventilating area per lineal foot.
Near ridge of the roof.